High Quality AC DC Single Output 40W LED Driver Power Supply
Basic Info
Model No.: S-40-12
Product Description
S-40-12
AC DC S-40-12
High quality/S-40-12
UL CE EMC S-40-12
2years warranty S-40-12 S-40-12 MEAN WELL/ * Universal AC input / Full range * Protections: Short circuit / Overload / Over voltage * Cooling by free air convection * 100% full load burn-in test * Fixed switching frequency at 75KHz * 2 years warranty
MODEL | S-40-5 | S-40-12 | S-40-15 | S-40-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 8A | 3.5A | 2.8A | 1.8A | |
CURRENT RANGE | 0 ~ 8A | 0 ~ 3.5A | 0 ~ 2.8A | 0 ~ 1.8A | |
RATED POWER | 40W | 42W | 42W | 43W | |
RIPPLE & NOISE (max.) Note.2 | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE Note.3 | 2.0% | 1.0% | 1.0% | 1.0% | |
LINE REGULATION | 0.5% | 0.5% | 0.5% | 0.5% | |
LOAD REGULATION | 1.0% | 0.5% | 0.5% | 0.5% | |
SETUP, RISE TIME | 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 70ms/230VAC 15ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 72%/115VAC | 76%/115VAC | 76%/115VAC | 78%/115VAC | |
AC CURRENT (Typ.) | 1.2A/115VAC 0.6A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 25A/115VAC 50A/230VAC | ||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25 | 27.6 ~ 32.4V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60 (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20 ~ +85 , 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50 ) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | UL1012, UL60950-1, TUV EN60950-1 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, light industry level, criteria A | ||||
MTBF | 314.1K hrs min. MIL-HDBK-217F (25 ) | ||||
DIMENSION | 129*98*38mm (L*W*H) | ||||
PACKING | 0.44Kg; 30pcs/13.9Kg/0.86CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Contact us if you need more details on Switching Power Supply. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Switch Power Supply、LED Switch Power Supply. If these products fail to match your need, please contact us and we would like to provide relevant information.